EO and ETO are abbreviations for ethylene oxide. Compare the listed tapes and chemical indicators by their intended use; select an indicator for the specified EO process rather than by colour or appearance alone.
Sterility Assurance and Monitoring/Indicators for Sterilization/Chemical Indicators for Sterilization/Autoclave Tapes/EO Sterilization/Autoclave Chemical Indicators/ Chemical Indicator Class 1
Mediwish Type 4 chemical indicator cards provide a clear red-to-blue color change after exposure to ethylene oxide (EO/ETO) under the specified process conditions. Designed for routine monitoring of EO sterilization cycles.
Process—Ethylene Oxide
Stated Value (SV)—600 mg/l EO, RH 60%, 30 °C, 30 minutes, 600 mg/l EO, RH 60%, 54 °C, 20 minutes.
Country of Origin—China
Sterilization Method—EO
Indicator Color Change—Initial color: Red. Final color: Blue.
Rectangular Type 4 EO chemical indicator strips, 16 × 90 mm, made from medical paper with water-based indicator ink. The band changes from red to blue during EO processing. Interpret the response with the supplied instructions and the required monitoring and release review.
Process—Ethylene Oxide
Product name—Rectangular EO chemical indicator strips
availability—OnOrder
Advantages—Clear and stable indicator
Features—Rectangular strip, 16 × 90 mm
Functions—Used to monitor and verify the EO gas sterilization process.
Introduction to Ethylene Oxide Sterilization Ethylene oxide (EO) sterilization is a crucial process in the healthcare industry, ensuring that medical devices and equipment are free from harmful microorganisms. It is a commonly used method due to its effectiveness in penetrating various materials and its ability to sterilize heat-sensitive and moisture-sensitive items. In order to ensure the safety and efficiency of this sterilization process, the use of chemical indicators is of utmost importance.
MEDIWISH Type 1-TEO ethylene oxide indicator tape in 12, 19, 22 or 25 mm widths × 50 m. Red-to-green indicator for external marking of wrapped items. Non-sterile, single use; store at 15–30 °C and 30–80% RH. Ordering article 62658.
Process—Ethylene Oxide
Application area—ethylene oxide sterilization
Product name—Gas indicator tape
Country of Origin—China
Instrument classification—class 1
OEM—available
Usage—External marking of wrapped items for ethylene oxide process exposure.
Sterilization Method—ETO
Applicable methods sterilization—Ethylene oxide (EO) process monitoring.
Indicator Color Change—red to green
Quantity in box—48/96
Product Size—12 mm x 50m; 19 mm x 50 m; 22 mm x 50m; 25 mm x 50 m; or custom-made size
Ethylene oxide is used in processes for some heat- or moisture-sensitive medical products. Suitability depends on the device, packaging, sterilizer and validated process; it is not a universal compatibility claim for plastics, electronics or assembled devices.
Temperature, humidity, exposure time and EO concentration are process variables to check in the selected equipment and indicator documentation. No cycle values are prescribed here. EO and ETO do not designate two different sterilants or establish whether the gas is pure or a mixture.
Preconditioning, exposure and subsequent aeration have different purposes. The equipment photograph illustrates an EO chamber; it does not establish the performance or validation of a particular load.
02
Photographs and process illustrations
EO sterilization chamber photograph. The image illustrates equipment, not the performance or validation of a specific cycle or load.
EO gas tape: verify the manufacturer’s colour reference, reading conditions, storage and expiry for this reference.
04
Use and interpretation
An EO chemical indicator provides the response defined for that model and intended process. Read its initial colour, reference endpoint and specified reading conditions in the instructions. The red-to-blue response belongs to the product explicitly named that way; it must not be applied to every indicator or tape.
Chemical response alone does not demonstrate sterility, adequate aeration or acceptable EO residues. Use the applicable equipment records, chemical and biological monitoring, validated aeration and residual-control procedures required for the device and process.
A tape used outside a package and an indicator intended for a specified position inside it provide different information. Do not substitute one for another solely because both change colour. Product classification and conformity require model-specific documentation.
05
Dimensions, packaging and handling
Check the reference, batch, expiry, packaging integrity and the indicator’s unused appearance before use. Choose the placement, attachment and reading method specified by the manufacturer and the facility procedure.
Record the indicator reference and lot with the load or process record as required. If the response is missing, incomplete or inconsistent with the specified endpoint, follow the facility investigation and disposition procedure; do not release a load on colour alone.
Storage, protection from unintended exposure and shelf life are product-specific. A previously exposed indicator must not be treated as an unused control. Confirm the single-use status of the selected product in its instructions.
06
Product documents and purchasing
EO handling requires suitable equipment, trained personnel and the applicable ventilation and occupational controls. A chemical indicator is not a workplace gas detector.
For purchasing, distinguish the indicator specification from the sterilizer, gas supply and aeration requirements. Request the relevant instructions and supporting reports for the exact reference and target market; this category page does not certify any model.
MEDIWISH · Process monitoring
Specify the process and product format
Send the product reference, sterilization method, packaging material, required dimensions, quantity and destination market. Ask for the model instructions, colour reference, shelf life, storage conditions and applicable technical documents.