Daily Sterilization Seal Test Paper checks the quality of seals on medical packaging. Test ensures seals are intact and meet sterilization standards by detecting issues like leaks or improper sealing. This helps maintain the sterility of medical instruments and supplies.
Ensure Flawless Sterilization: Daily Sterilization Seal Test Paper (High/Low Temp)
Protect your patients and maintain regulatory compliance with Mediwish's Daily Seal Test Paper! This essential tool allows for quick and easy verification of seal integrity on sterilization pouches, guaranteeing the sterility of your instruments.
Features & Benefits:
- High & Low Temperature Compatibility: Choose the test paper that best suits your sterilization process (e.g., steam vs. plasma) for optimal seal validation. We offer both high and low-temperature options.
- Laminated vs. Non-Laminated:
- Laminated: Provides an extra layer of protection and convenience, eliminating the need for additional packaging material. Perfect for quick seal quality tests.
- Non-Laminated: Designed for testing the sealability of your sterilization bags. Simply place it between the film and paper layers before sealing.
- Peace of Mind & Patient Safety: Visually confirm secure seals with a clear indicator (darker area) after sterilization. This ensures instruments remain sterile and prevents potential infections.
- Easy-to-Use: Simply fill out the information (date, operator, machine number) on the test card, place it inside the pouch (if laminated), and seal. After sterilization, inspect the card for any seal breaches.
- Compliance with Regulations: Regular seal testing is crucial for adhering to sterilization process validation requirements (ISO 11607-2).
Choosing the Right Seal Test Paper:
- Temperature: Use high-temperature test paper for machines operating above 180°C (356°F) and low-temperature for those below 120°C (248°F).
- Sterilization Method: For high-temperature steam sterilization, choose high-temperature test paper. For low-temperature plasma sterilization, choose low-temperature test paper (often made from Tyvek® paper).
View our product video for a detailed demonstration of how to use the Daily Sterilization Seal Test Paper.
Mediwish - Committed to Quality and Patient Safety
Order your Daily Seal Test Paper (100/200 sheets/box) today!
Additional Information:
- Available Models: We offer laminated and non-laminated test papers in both high and low-temperature options to suit your specific needs.
- Easy Documentation: The test card includes designated fields for recording sealer number, location, date, and approval signature, facilitating clear documentation for audits.
- Retrospective Verification: The visual indicator on the test paper provides a permanent record of seal quality, allowing for easy retrospective seal verification if needed.
Looking for additional sterilization packaging accessories? Explore our wide selection of products designed to ensure the integrity of your sterilization process.
The difference between laminated and non-laminated test card.
After correctly filling in the information (date, operator number, sealing machine number) on the front of the lamination test card, you need to cut off a piece of paper-plastic sterilization bag, put the test card inside between the film and paper, and then conduct a sealing experiment. After filling in the information on the lamination test card, there is no need to put the test in a plastic bag, you can directly test and seal the experiment, and the lamination test card is more convenient and of high quality.In Short: The difference between a test card and a lamination test card is that the lamination test card requires an additional step of placing the test card inside a plastic bag before conducting the sealing validation process.
How to choose high and low / low temperature test card.
How to choose the high and low temperature test cardMethod 1: For the sealing temperature of the sealing machine, a high-temperature test card should be selected for 180℃, and a low-temperature test card should be selected for 120℃;
Method 2: What type of disinfection sterilizer do you use, if the disinfection method is a high-temperature steam disinfection sterilizer, you should choose a high-temperature test card, if the disinfection method is a low-temperature plasma disinfection sterilizer, you should choose a low-temperature test card.
Tell us the selected products and whether you need private label or Mediwish branding. Availability, artwork, labeling, documents and commercial arrangements are confirmed for the product and destination market. Branding alone does not establish permission to market a product.
Send the product scope, required specification, artwork and target market. Customization options, feasibility, minimum quantities, samples, documentation and timing are reviewed for the specific project and confirmed in writing.
Send your request with the product name or model, required specifications, quantity and destination country. Product configuration and payment and delivery terms are agreed when the order is confirmed.







